Alarms that inform without blocking
Non-modal alarm management: acknowledge and silence without stopping operation, with critical, high, medium and warning severity.



ATILAX LiftOS controls field equipment —PCPs, heaters, pumps and more— with diagnostics, alarms and a record of who changed what. On the hydraulic pumping unit it cycles on its own, adjusts stroke by stroke and draws the live dynamometer card.
ATILAX LiftOS — Field equipment control, of the Atilax suite. VENECORR NDT brings it to market.
ContactTry the live demo ↗Non-modal alarm management: acknowledge and silence without stopping operation, with critical, high, medium and warning severity.

On the hydraulic pumping unit: diagnosis of rod parting, out-of-tolerance geometry, oil over-temperature, pump health and unreachable SPM.
On the hydraulic pumping unit: live surface dynamometer card with calibrated scale. Stroke control with lost-stroke detection and geometry health.
On the hydraulic pumping unit: automatic and manual mode, with software stop in the safe direction. Configuration and commissioning wizards, with change auditing.
Screenshot of the system in a demonstration scenario.